PENGARUH PENUNDAAN PEMERIKSAAN TERHADAP HASIL PEMERIKSAAN PARAMETER TROMBOSIT MENGGUNAKAN HEMATOLOGY ANALYZER

KARENI, LISYE ELSINA (2017) PENGARUH PENUNDAAN PEMERIKSAAN TERHADAP HASIL PEMERIKSAAN PARAMETER TROMBOSIT MENGGUNAKAN HEMATOLOGY ANALYZER. Other thesis, Universitas Sebelas Maret.

[img] PDF - Published Version
Download (41Kb)

    Abstract

    ABSTRAK Lisye Elsina Kareni, G0013138, 2016. Pengaruh Penundaan Pemeriksaan Terhadap Hasil Pemeriksaan Parameter Trombosit Menggunakan Hematology Analyzer. Skripsi. Fakultas Kedokteran, Universitas Sebelas Maret, Surakarta. Pendahuluan: Trombosit adalah salah satu sel darah yang berfungsi dalam faktor pembekuan darah. Penundaan pemeriksaan trombosit dapat mempengaruhi hasil jumlah trombosit, yang dapat menyebabkan penurunan jumlah trombosit. Tujuan dari penelitian ini untuk mengetahui adakah pengaruh penundaan pemeriksaan terhadap hasil pemeriksaan parameter trombosit dengan menggunakan alat Hematology Analyzer. Metode: Penelitian ini dengan metode cohort dan dilakukan di salah satu Laboratorium Swasta Terakreditasi di Surakarta pada bulan Oktober 2016. Pengambilan sampel menggunakan metode consecutive sampling dengan jumlah sampel sebanyak 30 spesimen darah. Variabel terikat pada penelitian ini adalah lima parameter trombosit yaitu Platelet (PLT), Platelet Distribution Width (PDW), Mean Platelet Volume (MPV), Platelet Crit (PCT), dan Platelet Large Cell Ratio (P-LCR). Sedangkan varibel bebas pada penelitian ini adalah lama waktu penundaan pemeriksaan. Sampel darah dikelompokkan dalam tiga kelompok: sampel yang langsung diperiksa setelah diterima (0 jam), di jam ke tiga dan jam keenam setelah dilakukan penundaan dengan menggunakan alat Sysmex XT-2000i. Teknik analisis data pada penelitian ini menggunakan uji One Way Anova bila sebaran data normal dan uji Kruskal-Wallis bila sebaran data tidak normal. Hasil: Sampel darah rutin yang didapat dari pasien laki-laki sebanyak 17 responden (57%) dan sampel darah rutin yang didapatkan dari pasien perempuan sebanyak 13 responden (43%). Hasil penelitian menunjukkan bahwa tidak terdapat perbedaan yang signifikan dalam jumlah PLT (0.909), PDW (0.936), MPV (0.925), PCT (0.934) dan P-LCR (0.935) pada sampel yang langsung diperiksa, pada jam ke tiga dan jam ke enam. Kesimpulan: Tidak terdapat perbedaan jumlah pada lima parameter trombosit yang signifikan pada penundaan pemeriksaan spesimen darah rutin hingga 6 jam menunggunakan Sysmex XT-2000i. Kata Kunci: Parameter trombosit, Penundaan pemeriksaan, Sysmex XT-2000i. ABSTRACK Lisye Elsina Kareni, G0013138, 2016. Effect of Examination Postponement to the Outcome of Platelet Count Parameters Using Hematology Analyzer. Mini Thesis, Faculty of Medicine SebelasMaret University, Surakarta. Introduction: Platelets are one of the blood cells that functions as blood clotting factors.Postponing platelet count is one of the factors that may affect platelet counts examination, in which it causes a decrease in the number of platelets. The aim of the research to determine the effect of examination to examination outcome of platelet count parameters using Hematology Analyzer. Methods: This cohort study was conducted in one of accredited private laboratories in Surakarta in October 2016. Consecutive sampling method was used in this study, and a total sample of 30 blood specimens was obtained. The dependent variables in this study are five platelet count parameters, namely platelet count (PLT), platelet distribution Width (PDW), mean platelet volume (MPV), platelet crit (PCT), and platelet large cell ratio (P-LCR). Independent variable in this study is duration of postponement of examination. Blood samples were grouped in three groups: samples that examined right after admission, in the third, and sixth hour after admission by using Sysmex XT-2000i. Data analysis was done by using One Way Anova for normal data distribution and the Kruskal-Wallis in the abnormal distribution settings. Result: Regular blood samples was obtained from seventeen male (57%) and thirteen female (43%) patients. The results showed that there was no significant difference in the number of PLT (0.909), PDW (0.936), MPV (0.925), PCT (0.934) and P-LCR (0.935) between sample examined after admission and in the third and the sixth hour after admission. Conclusion:No significant difference in five parameters of Platelet count was found between three groups of blood sample examined using Sysmex XT-2000i. Keywords :Platelet parameters; Examination Postponement; Sysmex XT-2000i.

    Item Type: Thesis (Other)
    Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
    Divisions: Fakultas Kedokteran > Pendidikan Kedokteran
    Depositing User: Kuni Nur Aini
    Date Deposited: 24 Mar 2017 08:17
    Last Modified: 24 Mar 2017 08:17
    URI: https://eprints.uns.ac.id/id/eprint/32249

    Actions (login required)

    View Item